Top Banner

3516 Land Electric-Drive Modules

Oil and gas drilling is a complex task that requires specialized power generation equipment. Cat 3500 generator sets are specifically designed for drilling operations of electric AC rigs. The 3500 platform carries decades of field experience in drilling operations across a wide variety of environmental conditions.Cat generator sets are backed by the worldwide network of Cat dealers ready to support your operation with technical support, service, parts, and warranty.3516 land drilling generator set. Ratings: 1256 ekW (1835 kVA) @ 60 Hz (1200 rpm). Not emissions certified, available for non-regulated areas.

3516

GET A QUOTE

A sales engineer replies within one working day.

The Catยฎ 3516 is built for reliable performance in the oil and gas range, backed by Al-Bahar's regional service and support network.

Minimum Rating
1245 ekW
Maximum Rating
1245 ekW
Emissions
Non-certified
Bore
6.69 in
Download Brochure
  • Specifications
  • Features
  • Standard Equipment

Specifications

Engine Specifications specifications
Minimum Rating 1245 ekW
Maximum Rating 1245 ekW
Emissions Non-certified
Bore 170 mm
Oil Change Interval 500 h
Generator SR4B
Aspiration Turbocharged-Aftercooled
Weight 18340 kg
Engine Control and Protection Woodward
Voltage 600
Stroke 190 mm
Displacement 69 l
Fuel System MUI

Features

Product Design

- Developed specifically to meet the demands of oil and gas applications- Proven reliability and durability- Robust diesel strength design prolongs life and lowers owning and operating costs- Designed to perform in oilfield conditions, including high ambient and high altitude applications- Market-leading power density- Designed to perform in oilfield conditions, including high ambient and high altitude applications- Long overhaul life proven in oilfield applications- Core engine components designed for reconditioningand reuse at overhaul

Ease of Installation

- Inner-outer base mounting configuration simplifies rigintegration- Wide range of attachments enable configurationflexibility- Inner base three-point generator mounting maintainsfactory alignment- Single lifting point simplifies installation work

Safety

- E-stop pushbutton on instrument panel- Air shutoff and explosion relief valves available- Extra alarms, inputs, and outputs available

Custom Packaging

For any petroleum application, trust Caterpillar to meet your project needs with custom factory generator sets and mechanical packages. Cat engines, generators, controls, radiators, and transmissions can be custom designed and matched in collaboration with our local dealers to create unique solutions. Custom packages are globally supported and are covered by a one year warranty after startup.

Testing

- Every Cat generator set is full-load tested to ensureproper engine performance.- Generator sets are assembled, tested, andvalidated as a package to ensure performance, reliabilityand durability.

Standard Equipment

Air Inlet System
  • Corrosion-resistant aftercooler core
  • Regular duty air cleaner
  • Service indicator
Control System
  • Governor, Woodward EG6PC actuator โ€” RH
  • Magnetic pickup
Cooling System
  • Thermostats and housing (dual outlet)
  • Jacket water pump, gear driven
Exhaust System
  • Dry exhaust manifold
  • Exhaust flexible fitting, adapters, and flanges
Flywheel and Housing
  • SAE No. 00 flywheel
  • SAE No. 00 flywheel housing
  • SAE standard rotation
Fuel System
  • Fuel filter
  • Fuel transfer pump
  • Flexible fuel lines
  • Fuel priming pump
Generator
  • Oilfield generator
  • Twin-bearing, close-coupled
Instrumentation
  • Analog instrument gauges:
Lubrication System
  • Crankcase breather
  • Oil cooler
  • Oil filter
  • Shallow oil pan
  • Oil drain extension, 2 in NPT female connection
Mounting System
  • Oilfield base 7.85 m (25 ft 9 in) length
  • Heavy-duty land rig inner baseframe โ€” three-point mount to oilfield base
Power take-offs
  • Accessory drive
  • Front housing, two-sided
Protection System
  • Hydra-mechanical shutoffs (low oil pressure, high water temperatureand overspeed, air inlet shutoff). Monitoring gauge and emergencyremote shutoff
  • Alarm switches, low oil pressure, high water temperature (MarineSociety approved) for connection to customer supplied alarm panel
  • Manual shutoff control, LH
Starting System
  • Air starting motor
  • Air silencer
General
  • Paint - Cat yellow
  • Vibration damper and guard
  • Lifting eyes

Optional Equipment

Air Inlet System

  • Heavy duty air cleaner
  • Remote air inlet adapters

Control System

  • Load sharing governor, 2301A
  • Load sharing module
  • Governor conversion to 0-200 mA direct rack control

Cooling System

  • Coolant level sensors
  • Connections

Exhaust System

  • Exhaust elbows
  • Exhaust mufflers

Fuel System

  • Primary fuel filter

Generator and Attachments

  • Low voltage extension box
  • Potential and current transformers
  • Air filter
  • Cable access box
  • Bearing RTDs

Instrumentation

  • Customer management device
  • Gauges and instrumentation panels
  • Switches and contactors

Lubrication System

  • Crankcase fumes disposal
  • Oil pan accessories

Mounting System

  • Bases

Power Take-off

  • Crankshaft pulley
  • Front stub shaft
  • Charging alternator

Protection System

  • Explosion relief valves (3)
  • Shutoffs
  • Switches and contactors

Starting System

  • Manual air starter
  • Air pressure regulator

General

  • Engine barring group