CTX Series Automatic Transfer Switch ATS MX Contactor

Catยฎ CTX Series switches are built for residential and light commercial applications requiring the dependability and ease of operation found in a power contactor switch.
Voltage sensing and system control is performed via a state-of-the-art microcontroller located on the cabinet door.

CTX Series Automatic Transfer Switch

GET A QUOTE

A sales engineer replies within one working day.

The Catยฎ CTX Series Automatic Transfer Switch is built for reliable performance in the electric power range, backed by Al-Bahar's regional service and support network.

Rating Range
40-400A
Transfer Type
Open transition
Switch Type
Contactor Based
Download Brochure
  • Specifications
  • Features
  • Standard Equipment

Specifications

Technical Summary specifications
Rating Range 40-400A
Transfer Type Open transition
Switch Type Contactor Based

Features

MX Control Panel

    CTX switches are equipped with the MX-60 control panel as standard.
    This microprocessor control includes:
  • Undervoltage sensing (90% pickup/80% dropout of the utility source
    • Voltage and frequency sensing of the generator source (90% voltage/95% frequency pickup)
    • Time Delay Engine Start โ€“ 5 seconds (P)
    • Time Delay Engine Warmup โ€“ Transfer to Generator โ€“ 20 seconds (W)
    • Time Delay Utility Stabilization/Retransfer to Utility โ€“ 5 minutes (T)
    • Time Delay Engine Cool Down โ€“ 5 minutes (U)

    All time delays are fixed.

Control Panel

adds a user interface and functionality

for power availability, switch position, and load energized

Pushbuttons for test, exercise set, timer bypass, and program cancel

status annunciation of in-phase transfer and times operation Selectable 7, 14, 21 or 28 day (factory set 28 days) generator exerciser timer

Diagnostic LED indications in logical one-line configuration

Standard Equipment

The unit is available in open type, NEMA 1 or NEMA 3R enclosures. The MX-60 control panel adds a user interface and functionality, including:
  • Pushbuttons for test, exercise set, timer bypass and program cancel
  • Special status annunciation of in-phase transfer and times operation
  • Diagnostic LED indications in logical one-line configuration
  • Selectable 7, 14, 21 or 28 day (factory set 28 days) generator exerciser timer
  • Indicating LEDs for power availability, switch position and load energized
Additional options include:
  • A3/A4 Auxiliary contacts (1 each) closed in utility and generator positions
  • Special timer settings