C13 (50 Hz) Diesel Generator Sets

The C13 diesel generator sets have been developed for your mission critical, standby and prime applications. Producing reliable power from 350 to 450 kVA at 50 Hz, our C13 diesel generator sets designed to ISO 8528-5 transient response requirements. These generator sets range from low fuel consumption systems EU Stage IIIA Non-road Emission Standards Emissions / Fuel Strategy.

C13 (50 Hz)

GET A QUOTE

A sales engineer replies within one working day.

C13 (50 HZ) 350-450 kVA Diesel Generator models represent a customizable and flexible solution for your mission critical, standby and prime applications.

Standby Rating
400/450 kVA
Prime Power Rating
350/400 kVA
Emissions/Fuel Strategy
Low BSFC
Voltage
380 to 415 Volts
Download Brochure
  • Specifications
  • Features
  • Standard Equipment

Specifications

Generator Set Specifications specifications
Standby Rating 400/450 kVA
Prime Power Rating 350/400 kVA
Emissions/Fuel Strategy Low BSFC
Voltage 380 to 415 Volts
Frequency 50 Hz
Speed 1500 rpm
Duty Cycle Standby, Prime

Features

Cat Generator Set Package

        
  • Cat generator set packages have been fully prototype tested
  •     
  • Accepts 100% block load in one step and meets NFPA 110 loading requirements
  •     
  • Conform to ISO 8528-5 steady state and transient response requirements

Cat Diesel Engine

        
  • Reliable, rugged, durable design
  •     
  • Field-proven in thousands of applications worldwide
  •     
  • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight

A-Frame Alternator

        
  • Superior motor starting capability minimizes need for oversizing alternator
  •     
  • Designed to match performance and output characteristics of Cat diesel engines
  •     
  • Robust Class H insulation

GCCP 1.3 Control Panel

        
  • User-friendly interface and navigation
  •     
  • Scalable system to meet a wide range of installation requirement
  •     
  • Expansion modules and site-specific programming for specific customer requirements

Cooling System

        
  • Designed to operate in standard ambient temperatures up to 55ยฐC (131ยฐF)
  •     
  • Contact your Cat Dealer for specific ambient and altitude capabilities

Standard Equipment

Air Inlet System
  • Turbocharger
  • Aftercooler core
  • Air cleaner; light duty with disposable paper filter
Control Panel
  • GCCP 1.3
Cooling System
  • Radiator and cooling fan with guard
  • Caterpillar extended life coolant
  • Fan drive, battery charging alternator drive
  • Coolant drain line with valve
Exhaust System
  • Stainless steel exhaust flex, gaskets, raincap & SAE exhaust flange for customer use - shipped loose
Fuel System
  • Base, formed steel with single wall integral 8-hour fuel tank
  • Standard open set fuel tank/base supplied
Generator and Attachments
  • Power center, IP22
  • Segregated low voltage (AC/DC) wiring panel
  • Optional LC Frame generator - IP23 Protection
  • Integrated voltage regulator (IVR)
  • Mandatory option circuit breaker, IEC, 3 pole, mounted in power centre
Packaged Generator Set
  • Coolant drain line with valve
  • Disposable air filter
  • Coolant level sight gauge
  • Low coolant level sensor
  • Radiator package mounted
Governing System
  • Cat electronic governor (ADEM A4)
Lube System
  • Oil drain valves
  • Lubricating oil
  • Oil cooler
Mounting System
  • Captive linear vibration isolators between base and engine-generator
  • Includes lifting provisions and termination points for coolant and lube oil drain lines
Starting / Charging System
  • 24V battery with rack and cables
General
  • Engine and alternator pre-paint, Caterpillar yellow

Optional Equipment

European Certificates

  • Global Certification for CIS
  • EU Certificate of Conformance (CE)

Air Inlet System

  • Dual element air cleaner
  • Single element air cleaner

Circuit breakers

  • Power terminal strip
  • 3 Pole (IEC-100% rated) Circuit breakers - Motorised
  • Circuit breaker (IEC) Auxiliary contacts
  • 4 Pole (IEC-100% rated) Circuit breaker - Motorised
  • Padlockable circuit breaker device

Control Panels

  • GCCP 1.4
  • Volt free contacts
  • Control panel protective devices: Earth fault relay ; Earth leakage ground fault ; Overload shutdown via breaker ; Low fuel level alarm ; Low fuel level shutdown ; High fuel level alarm ; Fuel level sensor
  • Local alarm modules: Local annunciator
  • Remote annunciator module

Cooling System

  • Stone guards
  • Radiator duct flange
  • Low coolant temperature alarm

Enclosures

  • High ambient sound attenuated enclosures
  • Sound attenuated enclosures

Exhaust System

  • 10, 25 and 35 dBA attenuation
  • Mufflers - End in/end out
  • 6 and 8 inch flange GP
  • 6 and 8 inch elbow kit
  • Flexible 8 inch exhaust fittings

Fuel System

  • Manual fuel transfer pump
  • Optional BS799 Compliant Integral dual wall fuel tank base
  • Fuel transfer system controls

Generator and Attachments

  • A Frame oversize generator
  • Permanent magnet excitation (PMG) generator
  • Ingress protection
  • A Frame CIP generator
  • LC frame generator

Lube System

  • Manual sump pump

Mounting System

  • Narrow skid base

starting / Charging System

  • Battery disconnect switch
  • 5 Amp single Battery charger
  • Jacket water heater