C18 (50 Hz) Diesel Generator Sets

The C18 diesel generator sets have been developed for your mission critical, standby and prime applications. Producing reliable power from 550 to 715 kVA at 50 Hz, meeting ISO 8528-5 transient response requirements and built to accept 100 % rated load in one step. Our C18 generator sets range from Low Fuel Consumption, Low Emissions and China Nonroad III Emission Standards Emissions / Fuel Strategy.

C18 (50 Hz)

GET A QUOTE

A sales engineer replies within one working day.

C18 (50 HZ) 550-715 kVA Diesel Generator models offer a broad range of attachments & fuel strategies to give customizable, reliable power fit to your needs.

Standby Rating
605/660/715/780/850 kVA
Prime Power Rating
550/600/650/706/770/600 kVA
Emissions/Fuel Strategy
China Non-Road Stage III Certified / Non-Certified Emissions
Voltage
380 to 415 Volts
Download Brochure
  • Specifications
  • Features
  • Standard Equipment

Specifications

Generator Set Specifications specifications
Standby Rating 605/660/715/780/850 kVA
Prime Power Rating 550/600/650/706/770/600 kVA
Emissions/Fuel Strategy China Non-Road Stage III Certified / Non-Certified Emissions
Voltage 380 to 415 Volts
Frequency 50 Hz
Speed 1500 rpm
Duty Cycle Standby, Prime

Features

Cat Generator Set Package

        
  • Cat generator set packages have been fully prototype tested
  •     
  • Accepts 100% block load in one step and meets NFPA 110 loading requirements
  •     
  • Conform to ISO 8528-5 steady state and transient response requirements

Cat Diesel Engine

        
  • Reliable, rugged, durable design
  •     
  • Field-proven in thousands of applications worldwide
  •     
  • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight

A-Frame Alternator

        
  • Superior motor starting capability minimizes need for oversizing alternator
  •     
  • Designed to match performance and output characteristics of Cat diesel engines
  •     
  • Robust Class H insulation

GCCP1.3 Control Panel

        
  • User-friendly interface and navigation
  •     
  • Scalable system to meet a wide range of installation requirement
  •     
  • Expansion modules and site-specific programming for specific customer requirements

Cooling System

        
  • Designed to operate in standard ambient temperatures up to 55ยฐC (131ยฐF)
  •     
  • Contact your Cat Dealer for specific ambient and altitude capabilities

Standard Equipment

Air Inlet System
  • Turbocharger
  • Light duty air cleaner
  • Aftercooler core
Air Inlet
  • Air cleaner
Control System
  • GCCP 1.2
Exhaust
  • Exhaust flange outlet
Cooling
  • Coolant drain line with valve
  • Caterpillar extended life coolant
  • Fan drive, battery charging alternator drive
  • Radiator and cooling fan with guard
Exhaust System
  • Stainless steel exhaust flex gaskets, raincap and SAE exhaust flange for customer use - shipped loose
Fuel
  • Secondary fuel filters
  • Fuel priming pump
  • Primary fuel filter with integral water separator
Fuel System
  • Standard 8 hour open set fuel tank
Generator
  • IP23 Protection
  • Load adjustment module provides engine relief upon load impact and improves load acceptance and recovery time
  • Matched to the performance and output characteristics of Cat engines
Generator and Attachments
  • Segregated low voltage (AC/DC) wiring panel
  • Integrated voltage regulator (IVR)
  • A Frame generator - IP21 protection
  • Integrated voltage regulator (IVR)
  • Mandatory option circuit breaker, IEC, 3 pole, mounted in power centre
Power Termination
  • Busbar
Governing System
  • Cat electronic governor (ADEM A4)
Control Panel
  • GCCP Genset Controller
Lube System
  • Lubricating oil
  • Oil drain valves
Mounting
  • Rubber vibration isolators
Mounting System
  • Captive linear vibration isolators between base and engine-generator. includes lifting provisions and termination points for coolant and lube oil drain lines
Starting/Charging
  • 24 Volt battery with rack and cables
General
  • Engine and alternator pre-paint, Caterpillar yellow

Optional Equipment

Exhaust

  • Industrial, residential, critical mufflers

Air Inlet System

  • Dual element air cleaner
  • Single element air cleaner

Circuit breakers

  • 3 Pole (IEC-100% rated) Circuit breakers - Motorised
  • 4 Pole (IEC-100% rated) Circuit breakers - Motorised
  • Circuit breaker (IEC) Auxiliary contacts
  • Padlockable circuit breaker device
  • 3 Pole (IEC-100% rated) Circuit breakers - Package mounted

Generator

  • Anti-condensation heater
  • Excitation: [ ] Permanent magnet excitation (PMG) Excited (PM) [ ] Internally Excited (IE)
  • Oversize and premium generators

Power Termination

  • Circuit breakers, IEC compliant
  • Circuit breakers, UL listed

Control Panels

  • Local & remote annunciator modules
  • Load share module
  • Remote monitoring software
  • EMCP (4.2) (4.3) (4.4)
  • Digital I/O module

Control System

  • Oil temperature displays
  • GCCP 1.5
  • Volt free contact
  • Protective devices: Earth fault relay - earth leageage Ground fault relay - Overload shutdown via breaker - Low fuel level alarm - Low fuel level shutdown - High fuel level alarm - Fuel level sensor
  • Local alarm modules

Cooling System

  • Low coolant temperature alarm
  • Radiator duct flange

Starting/Charging

  • Oversize batteries
  • Jacket water heater
  • Battery chargers
  • Heavy duty starting system
  • Charging alternator

Enclosures

  • Sound attenuated enclosures

Exhaust System

  • Manifold and turbocharger guards
  • Engine mounted muffler
  • 8 and 10 inch elbow kits
  • 8 and 10 inch GP flanges
  • 10, 25 and 35 end in / end outmufflers

Fuel System

  • Optional BS799 Compliant Integral - Dual wall fuel tank base
  • Manual fuel transfer pump
  • Fuel transfer system

Generator and Attachments

  • LC frame generator
  • Permanent magnet excitation (PMG)
  • LC frame oversize generators
  • Space heaters
  • A Frame oversize generator

General

  • Single or dual wall integral fuel tanks
  • UL 2200 package
  • Enclosures: Sound attenuated, weather protective
  • EU Certificate of Conformance (CE)
  • Integral & sub-base UL listed dual wall fuel tanks

Lube System

  • Manual sump pump

Starting and Charging

  • Jacket water heaters
  • 5 Amp Battery charger
  • Battery disconnect switch