Top Banner

C9 (50 Hz) Diesel Generator Sets

Producing reliable power from 230 to 330 kVA at 50 Hz, our C9 diesel generator sets designed to ISO 8528-5 transient response requirements. All C9 generator sets are engineered to EPA Stationary Emergency (Tier 3) emissions standards.

C9 (50 Hz)

GET A QUOTE

A sales engineer replies within one working day.

C9 (50 HZ) 230-330 kVA Diesel Generator generator sets are made to fufill current and future standby and prime applications with reliable power.

Standby Rating
250/275/300/330 kVA
Prime Power Rating
230/250/275/300 kVA
Emissions/Fuel Strategy
Non-Certified Emissions / EU Stage IIIA
Voltage
200 to 400 Volts
Download Brochure
  • Specifications
  • Features
  • Standard Equipment

Specifications

Generator Set Specifications specifications
Standby Rating 250/275/300/330 kVA
Prime Power Rating 230/250/275/300 kVA
Emissions/Fuel Strategy Non-Certified Emissions / EU Stage IIIA
Voltage 200 to 400 Volts
Frequency 50 Hz
Speed 1500 rpm
Duty Cycle Standby, Prime

Features

Cat Generator Set Package

        
  • Cat generator set packages have been fully prototype tested
  •     
  • Accepts 100% block load in one step and meets NFPA 110 loading requirements
  •     
  • Conform to ISO 8528-5 steady state and transient response requirements

R-Frame Alternator

        
  • Superior motor starting capability minimizes need for oversizing alternator
  •     
  • Designed to match performance and output characteristics of Cat diesel engines
  •     
  • Robust Class H insulation

Cat Diesel Engine

        
  • Reliable, rugged, durable design
  •     
  • Field-proven in thousands of applications worldwide
  •     
  • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight

GCCP1.3 Control Panel

        
  • User-friendly interface and navigation
  •     
  • Scalable system to meet a wide range of installation requirement
  •     
  • Expansion modules and site-specific programming for specific customer requirements

Cooling System

        
  • Designed to operate in standard ambient temperatures up to 55ยฐC (131ยฐF)
  •     
  • Contact your Cat Dealer for specific ambient and altitude capabilities

Standard Equipment

Air Inlet System
  • Air cleaner, light duty with disposable paper filter
Control Panels
  • GCCP 1.3
Cooling System
  • Fan drive, battery charging alternator drive
  • Radiator and cooling fan with guard
  • Caterpillar extended life coolant
  • Coolant drain line with valve
Exhaust System
  • Stainless steel exhaust flex, gaskets, rain cap & SAE exhaust flange for customer use - shipped loose
Fuel System
  • Base, formed steel with single wall integral 8-hour fuel tank
  • Standard open set fuel tank/base supplied
Generators and Generator Attachments
  • 12 Leads
  • Mandatory option circuit breaker, IEC, 3 pole mounted in power centre
  • Voltage regulator (single phase sensing)
  • Segregated low voltage (AC/DC) wiring panel
  • IP23 Protection
Governing System
  • Cat electronic governor (ADEM A4)
Lube System
  • Oil drain valves
  • Lubricating oil
  • Oil cooler
Mounting System
  • Includes lifting provisions and termination points for coolant and lube oil drain lines
  • Captive linear vibration isolators between base and engine-generator
Starting / Charging System
  • 24V battery with rack and cables
General
  • Engine and alternator re-paint, Caterpillar yellow

Optional Equipment

Certifications

  • European Certificate for Conformance
  • Global Certification for CIS

Air inlet system

  • Single element air cleaner

Circuit breakers

  • 4 Pole (IEC-100% rated) Circuit breaker upgrades: 400, 630, 800 and 100 amps

Control Panels

  • Control panel protective devices: Earth fault relay ; Earth leakage ground fault ; overload shutdown via breaker ; Low fuel level shutdown ; Low fuel level alarm ; Fuel level sensor
  • Control panel Options: Volt free contacts ; Local alarm horn ; Oil temperature displays

Cooling System

  • Radiator duct flange
  • Low coolant temperature alarm

Enclosures

  • Sound attenuated enclosure
  • High ambient sound attenuated enclosure

Exhaust System

  • 5 and 6 inch elbow kits
  • 5 - 6 inch flange adaptor
  • Mufflers - End in/end out; 10 dBA or 25 dBA attenuation
  • 6 inch flange

Fuel System

  • Integral dual wall fuel tank base

Generators and Attachments

  • Permanent magnet excitation (PMG) generator
  • Oversize, AREP, CIP generators

Mounting System

  • Narrow skid base

Starting / Charging System

  • Jacket water heater
  • 5 Amp single Battery charger
  • Battery disconnet switch