Top Banner

3512B (50 Hz) 1320 -1625 kVA Diesel Generator Sets

Producing reliable power from 1320 to 1625 kVA at 50 Hz, our 3512B diesel generator sets are made to meet your mission critical, continuous, standby and prime applications. We've designed each to ISO 8528-5 transient response requirements and to accept 100% rated load in one step. Generator sets offer both low fuel consumption and low emission systems.

3512B (50 Hz) 1320 -1625 kVA

GET A QUOTE

A sales engineer replies within one working day.

3512B (50 HZ) 1320-1875 kVA Diesel Generator models offer a great degree of customization for mission critical, continuous, standby and prime applications.

Standby Rating
1625/1600/1500 kVA
Prime Power Rating
1500/1360 kVA
Emissions/Fuel Strategy
Low Fuel, Low Emissions
Voltage
380 to 415 Volts
Download Brochure
  • Specifications
  • Features
  • Standard Equipment

Specifications

Generator Set Specifications specifications
Standby Rating 1625/1600/1500 kVA
Prime Power Rating 1500/1360 kVA
Emissions/Fuel Strategy Low Fuel, Low Emissions
Voltage 380 to 415 Volts
Frequency 50 Hz
Speed 1500 rpm
Duty Cycle Standby, Mission Critical, Prime
Maximum Rating 1625 kVA
Minimum Rating 1320 kVA

Features

Cat Generator Set Package

  • Cat generator set packages have been fully prototype tested
  • Accepts 100% block load in one step and meets NFPA 110 loading requirements
  • Conform to ISO 8528-5 steady state and transient response requirements

Cat Diesel Engine

  • Reliable, rugged, durable design
  • Field-proven in thousands of applications worldwide
  • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight

SR5 Alternator

  • Superior motor starting capability minimizes need for oversizing alternator
  • Designed to match performance and output characteristics of Cat diesel engines
  • Robust Class H insulation

Cat ECS Control Panel

  • User-friendly interface and navigation
  • Scalable system to meet a wide range of installation requirement
  • Expansion modules and site-specific programming for specific customer requirements

Cooling System

        
  • Designed to operate in standard ambient temperatures up to 50ยฐC (122ยฐF)
  •     
  • Contact your Cat Dealer for specific ambient and altitude capabilities

Standard Equipment

Air Inlet System
  • Aingle element canister type air cleaner with service indicator
Air Inlet
  • Air cleaner
Cooling
  • Package mounted radiator (except C175)
Control Panel
  • Emergency stop button
  • Programmable protective relaying functions:
  • Over/under voltage (27 / 59)
  • kVAr (per phase, average & percent)
  • kVA (per phase, average & percent)
Exhaust
  • Exhaust flange outlet
Fuel
  • Secondary fuel filters
  • Primary fuel filter with integral water separator
  • Fuel priming pump
Control System
  • Engine cool-down timer
  • DC volts
  • True RMS AC metering, 3-phase, +/-2% accuracy
  • High coolant temperature
  • Coolant temperature
Generator
  • IP23 Protection
  • Matched to the performance and output characteristics of Cat engines
Power Termination
  • Busbar
Generator System
  • Class H temperature rise at 40C ambient
  • 3 phase brushless, Salient pole
  • 6 Lead
  • Winding temperature detectors
  • NEMA Class H insulation
Literature
  • Parts book
  • Operation & Maintenance Manual
Cooling System
  • Caterpillar extended life coolant. (Not included with packages without radiator, installed SF44CTS, shipped loose radiators or heat exchangers)
  • JWAC
  • Coolant level sensors (Not included with packages without radiator)
  • Coolant drain line with valve
  • Radiator fan and fan drive
Exhaust System
  • Dry exhaust manifold
  • Flanged faced outlet(s)
Fuel System
  • Fuel priming pump
  • Secondary fuel filters
  • Fuel cooler; not included with packages without radiator
  • Flexible fuel lines - shipped loose
Generators and Attachments
  • Note: 1800 Frames are form wound, permanent magnet excitation (PMG), with winding temp detectors
  • 3 Phase voltage sensing
  • RFI suppression
  • Class H temperature rise at 40C ambient (125C prime / 150C standby)
  • Min / max exciter limiter
Governing System
  • Woodward 2301A isochronous governor
Lube System
  • Lubricating oil
  • Gear type lube oil pump
  • Integral lube Oil cooler
  • Oil filter, filler and dipstick
  • Fumes disposal
Mounting System
  • Rails - Engine/generator/radiator mounting
  • Rubber anti-vibration mounts - shipped loose
Starting / Charging System
  • Battery disconnect switch
  • Battery and battery rack w/cables
  • 24 Volt electric starting motor
General
  • SAE standard rotation
  • Flywheel and Flywheel housing-SAE No. 00
  • RH service
  • Paint - Caterpillar yellow with high gloss black rails & radiator

Optional Equipment

Air Inlet System

  • Air inlet protection
  • Remote air inlet adaptors
  • Dual element air cleaners

Exhaust

  • Exhaust mufflers

Generator

  • Anti-condensation heater
  • Internal excitation (IE)
  • Permanent magnet excitation (PMG)
  • Oversize and premium generators

Circuit breakers

  • Cable entry options
  • 2000, 2500, 3200 and 4000 Amp, 4 pole, IEC rated Circuit breakers
  • Busbar connections
  • Center posts busbars
  • Controls packaging - Enclosures

Power Termination

  • Circuit breakers, UL listed
  • Circuit breakers, IEC compliant

Control Panels

  • Annunciator modules
  • Customer connection mounting locations
  • Remote speed adjust
  • Local PC monitoring
  • Generator temperature monitoring

Mounting

  • Rubber anti-vibration mounts
  • IBC isolators
  • Spring type vibration isolators

Starting/Charging

  • Oversize batteries
  • Air starting motor with control and silencer
  • Jacket water heater
  • Heavy duty starting system
  • Charging alternator

Cooling System

  • Water level switch gauges
  • Optional radiator arrangements
  • Heat exchangers

European Certifications

  • European Union certification
  • EU Declaration of Conformity
  • European Directive genset, DoI (Declaration of Incorporation)
  • Eurasian Conformity (EAC) mark

Exhaust System

  • Mufflers
  • Muffler mounting kits
  • Through-wall installation kit
  • Flexible fittings

Fuel System

  • Primary fuel filter

Generators and Attachments

  • Generator conversion
  • 1500 RPM, 380/400/415volts @ 50 Hz, 3 phase, random wound, Permanent magnet excitation (PMG), No. of leads = 6, pitch= 0.6667
  • 1500 RPM, 380/400/415volts @ 50 Hz, 3 phase, Form wound, Permanent magnet excitation (PMG), No. of leads = 6, pitch= 0.6667
  • 1500 RPM, 380/400/415volts @ 50 Hz, 3 phase, random wound, Internal excitation (IE), No. of leads = 6, pitch= 0.6667
  • Space heater

Instrumentation

  • Pyrometer and thermocouples

Lube System

  • Oil level reg-1 shallow pan
  • Electric prelube pumps
  • Manual prelube sump pumps

Mounting System

  • IBC vibration isolators
  • Spring type vibration isolators

Protection System

  • Explosion relief valves

Special Tests / Reports

  • PGS Test report @ 0.80 power factor
  • Neutral ground-LV
  • IBC seismic Certifications
  • PGS Test report @ 1.0 power factor
  • Neutral grounding connection

Starting / Charging System

  • Oversize battery set
  • Jacket water heaters
  • 10 Amp Battery chargers
  • Ether starting aid
  • 24 Volt dual electric starting motor

General

  • Engine barring group