Top Banner

G3520 with FAST RESPONSE Gas Generator Sets

Caterpillar is leading the power generation marketplace with Fast Response generator sets engineered to deliver unmatched performance, reliability, and cost-effectiveness.

G3520 with FAST RESPONSE

GET A QUOTE

A sales engineer replies within one working day.

Catยฎ G3520 (1750kW-2500kW) Natural Gas Generator models are recognized as a symbol of power generation versatility due to many proven industry applications.

Gas Standby Rating
2500 ekW @ 0.8pf
Fuel Type
Natural Gas, Hydrogen Blend (up to 5%)
Emissions/Fuel Strategy
U.S. EPA Stationary Non-Emergency Certified
RPM
1800 rpm
Download Brochure
  • Specifications
  • Features
  • Standard Equipment

Specifications

Generator Set Specifications specifications
Gas Standby Rating 2500 ekW @ 0.8pf
Fuel Type Natural Gas, Hydrogen Blend (up to 5%)
Emissions/Fuel Strategy U.S. EPA Stationary Non-Emergency Certified
RPM 1800 rpm
Frequency 60 Hz
Compression Ratio 11.5

Features

Cat G3520 Gas Engine

        
  • Robust high speed block design provides prolonged life and lower owning operationg costs
  •     
  • Designed for maximum performance on low pressure pipeline natural gas and hydrogen blends
  •     
  • Simple open chamber combustion system for reliability and fuel flexibility
  •     
  • Leading edge technology in ignition system and air/fuel ratio control for lower emission and engine efficiency
  •     
  • One electronic control module handles all engine functions: ignition, governing, air/fuel ratio control and engine protection

Full Range of Attachments

        
  • Wide range of bolt-on system expansion attachments
  •     
  • Factory designed and tested
  •     
  • Flexible packaging options for easy and cost effective installation

Worldwide Product Support

        
  • Cat dealers have over 1,800 dealer branch stores operating in 200 countries
  •     
  • Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements

SR5 Generator

        
  • Designed to match performance and output characteristics of Caterpillar gas engines
  •     
  • Industry leading mechanical and electrical design
  •     
  • High efficiency

Cat ECS 100 Control Panel

        
  • User-friendly interface and navigation
  •     
  • Scalable system to meet a wide range of installation requirement
  •     
  • Expansion modules and site-specific programming for specific customer requirements

Standard Equipment

Air Inlet
  • Two-element single-stage air cleaner with enclosure and service indicator
Control Panel
  • Cat ECS 100
Cooling
  • Jacket water and SCAC engine-driven pumps
  • Jacket water and SCAC thermostats
Exhaust
  • Cat-flanged face outlet on turbocharger
  • Individual exhaust port and turbocharger outlet wired to integrated temperature sensing module (ITSM) with GCEM providing alarms and shutdowns
  • Dry exhaust manifolds, insulated and shielded
Fuel System
  • Gas pressure regulator
  • Engine-installed electronic control valve
  • Fuel system is sized for 31.5 to 47.2 MJ/NM3 dry pipeline natural gas with pressure of 10.2 to 34.5KPa to the engine fuel control valve
  • 24V DC energized-to-run (ETR) gas shutoff valve
  • Throttle plate, 24V DC actuator, controlled by GECM
General
  • Crankshaft vibration damper and guard
  • Operation and maintenance manuals
  • RH Service
  • Paint- Caterpillar Yellow with high gloss black rails and radiator
  • Parts book
Generator
  • SR5
  • Permanent Magnet Excitiation
  • NEMA Class H insulation
  • Winding temperature detectors
  • Integrated voltage regulator (IVR)
Starting/Charging
  • Battery with cables and rack (shipped loose)
  • 24V starting motors
  • Electric Starter
  • Jacket water heater
Governing System
  • ADEM A4
Ignition System
  • Electronic Ignition System (controlled by ADEM A4)
  • Individual Cylinder Detonation Sensitive Timing (DST)

Optional Equipment

Air Inlet

  • Air cleaner with precleaner

Control Panel

  • Local alarm module
  • EMCP 4.4
  • Remote annunciator
  • Remote PC monitoring
  • Engine failure relay

Circuit Breakers

  • 2000A, 2500A, 3000A 3 Pole, UL-100% Rated Masterpact Circuit Breakers
  • 100% rated, 3-pole (UL/CSA/IEC) 5th Digit Rating
  • 3-pole (IEC 947-2 rated)
  • Frame mounting
  • 1600A, 2000A 3 Pole, UL-100% Rated R-Frame Circuit Breakers

Cooling

  • Coolant level drain line with valves, fan with guard
  • Package mounted radiator

Exhaust

  • 305 mm (12 in.) muffler
  • 305 mm (12in.) elbow
  • 18, 25 dBA Attenuation
  • 305 mm (12 in.) flange
  • 305mm (12 in) spark arresting muffler

Fuel System

  • 3, 0-100 kPag, 4-20mA gas train pressure sensors

General

  • Digital diagnostic tool

Generator

  • Low voltage extension box
  • Bearing temperature detectors
  • European bus bars
  • Cable access box
  • Generator air filter

Starting/Charging

  • 45A, 24V charging alternator (requires engine driven pumps)
  • 20A, 24VDC battery charger

Grid Code Compliance

  • 60 Hz: USA