Top Banner

DE33 GC (60 Hz) Diesel Generator Sets

The Catยฎ C3.3 diesel generator sets have been developed for standby applications, delivering reliable power from 30 ekW at 60 Hz, meeting ISO 8528-5 transient response requirements.

DE33 GC (60 Hz)

GET A QUOTE

A sales engineer replies within one working day.

DE33 GC (60 HZ) C3.3, 30 kW Diesel Generator models' range of accessories, emissions level & other options allow customers to customize for their needs.

Standby Rating
30 ekW
Frequency
60 Hz
Emissions/Fuel Strategy
Low BSFC
Voltage
220 to 480 Volts
Download Brochure
  • Specifications
  • Features
  • Standard Equipment

Specifications

Generator Set Specifications specifications
Standby Rating 30 ekW
Frequency 60 Hz
Emissions/Fuel Strategy Low BSFC
Voltage 220 to 480 Volts
Speed 1800 rpm
Duty Cycle Standby

Features

Cat Generator Set Package

  • Cat generator set packages have been fully prototype tested
  • Accepts 100% block load in one step and meets NFPA 110 loading requirements
  • Conform to ISO 8528-5 steady state and transient response requirements

Cat Diesel Engine

  • Reliable, rugged, durable design
  • Field-proven in thousands of applications worldwide
  • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight

A-Frame Alternator

  • Superior motor starting capability minimizes need for oversizing alternator
  • Designed to match performance and output characteristics of Cat diesel engines
  • Robust Class H insulation

GCCP 1.1 Control Panel

  • User-friendly interface and navigation
  • Scalable system to meet a wide range of installation requirement
  • Expansion modules and site-specific programming for specific customer requirements

Cooling System

  • Designed to operate in standard ambient temperatures up to 55ยฐC (131ยฐF)
  • Contact your Cat Dealer for specific ambient and altitude capabilities

Standard Equipment

Engine
  • C3.3, Inline 3 cylinder, 4 stroke diesel
Genset Control
  • GCCP 1.1
Governor
  • Mechanical governor
Alternator
  • A Frame standard alternator
Fuel Storage
  • Single wall 8 hour fuel tank
Enclosure
  • Cat GC enclosure
Air, Cooling & Exhaust
  • Enclosure silencer
General
  • Engine and alternator pre-paint, Caterpillar yellow

Optional Equipment

Certification

  • Certificate of Conformance
  • Australia, CIS, Gulf Certification

Alternator Requirements

  • Space heater

Auxiliary Supply Voltage

  • 120V

Fuel Storage

  • Dual wall 8 hour fuel tank
  • Low fuel level shutdown
  • Single wall tank with containment
  • Low fuel level alarm
  • High fuel level alarm

Genset Control

  • Battery charger
  • Volt free contacts for genset running
  • Volt free contacts for common alarm
  • Earth fault
  • Panel mounted audible alarm

Circuit breaker

  • 3 Pole Circuit breaker 80A
  • 3 Pole Circuit breaker 63A
  • 3 Pole Circuit breaker 100A
  • 3 Pole Circuit breaker 125A
  • 3 Pole Circuit breaker 160A

Testing & Packaging

  • PGS Test report @ 1.0 power factor
  • PGS Test report @ 0.8 power factor

Package

  • Open Set