Top Banner

DE110 GC (50 Hz) Diesel Generator Sets

The Catยฎ C4.4 diesel generator sets have been developed for standby and prime power applications, delivering reliable power from 110 kVA at 50 Hz, meeting ISO 8528-5 transient response requirements.

DE110 GC (50 Hz)

GET A QUOTE

A sales engineer replies within one working day.

DE110 GC (50 HZ) C4.4, 110 kVA Diesel Generator models' range of accessories, emissions level & other options allow customers to customize for their needs.

Standby Rating
110 kVA
Frequency
50 Hz
Emissions/Fuel Strategy
Low BSFC
Voltage
380 to 415 Volts
Download Brochure
  • Specifications
  • Features
  • Standard Equipment

Specifications

Generator Set Specifications specifications
Standby Rating 110 kVA
Frequency 50 Hz
Emissions/Fuel Strategy Low BSFC
Voltage 380 to 415 Volts
Speed 1500 rpm
Duty Cycle Standby

Features

Cat Generator Set Package

  • Cat generator set packages have been fully prototype tested
  • Accepts 100% block load in one step and meets NFPA 110 loading requirements
  • Conform to ISO 8528-5 steady state and transient response requirements

Cat Diesel Engine

  • Reliable, rugged, durable design
  • Field-proven in thousands of applications worldwide
  • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight

A-Frame Alternator

  • Superior motor starting capability minimizes need for oversizing alternator
  • Designed to match performance and output characteristics of Cat diesel engines
  • Robust Class H insulation

GCCP 1.1 Control Panel

  • User-friendly interface and navigation
  • Scalable system to meet a wide range of installation requirement
  • Expansion modules and site-specific programming for specific customer requirements

Cooling System

  • Designed to operate in standard ambient temperatures up to 55ยฐC (131ยฐF)
  • Contact your Cat Dealer for specific ambient and altitude capabilities

Standard Equipment

Engine
  • C4.4, Inline 4 cylinder, 4 stroke diesel
Genset Control
  • GCCP 1.1
Governor
  • Mechanical governor
Fuel Storage
  • Single wall 8 hour fuel tank
Alternator
  • A Frame standard alternator
Enclosure
  • Cat GC enclosure
Air, Cooling & Exhaust
  • Enclosure silencer
General
  • Engine and alternator pre-paint, Caterpillar yellow

Optional Equipment

Certification

  • Certificate of Conformance 13
  • Australia, CIS, Gulf Certification

Auxiliary Supply Voltage

  • 120V

Alternator Requirements

  • Space heater

Fuel Storage

  • Dual wall 8 hour fuel tank
  • Single wall tank with containment
  • High fuel level alarm
  • Low fuel level alarm
  • Low fuel level shutdown

Genset Control

  • Volt free contacts for common alarm
  • Panel mounted audible alarm
  • Earth fault
  • Volt free contacts for genset running
  • Emergency stop with key

Circuit breaker

  • 3 Pole Circuit breaker 125A
  • 3 Pole Circuit breaker 160A
  • 3 Pole Circuit breaker 200A
  • 4 Pole Circuit breaker 125A
  • 3 Pole Circuit breaker 400A

Testing & Packaging

  • PGS Test report @ 1.0 power factor
  • PGS Test report @ 0.8PF