The 3516E diesel generator sets have been developed to meet your continuous, standby and prime applications and match your power standards. Producing reliable power from 2750 to 3000 kVA (3100 kVA without fan) at 50 Hz, each generator set has been designed to meet ISO 8528-5 transient response requirements and to accept 100 % rated load in one step. The generator set offers a low fuel consumption system.

Catยฎ 3516E (50 Hz) with Upgradable Package

GET A QUOTE

A sales engineer replies within one working day.

3516E (50 HZ) 2750-3100 kVA Diesel Generator models can be customized to meet your continuous, standby & prime applications & match your power standards.

Standby Rating
3000 kVA (3100 kVA without fan)
Prime Power Rating
2750 kVA (2850 kVA without fan)
Emissions/Fuel Strategy
Low Fuel Consumption
Voltage
380 to 11000 volts
Download Brochure
  • Specifications
  • Features
  • Standard Equipment

Specifications

Generator Set Specifications specifications
Standby Rating 3000 kVA (3100 kVA without fan)
Prime Power Rating 2750 kVA (2850 kVA without fan)
Emissions/Fuel Strategy Low Fuel Consumption
Voltage 380 to 11000 volts
Frequency 50 Hz
Speed 1500 rpm
Duty Cycle Standby, Mission Critical, Prime
Maximum Rating 3000 kVA (3100 kVA without fan)
Minimum Rating 2750 kVA (2850 kVA without fan)

Features

Cat Generator Set Package

  • Cat generator set packages have been fully prototype tested
  • Accepts 100% block load in one step and meets NFPA 110 loading requirements
  • Conform to ISO 8528-5 steady state and transient response requirements

Cat Diesel Engine

  • Reliable, rugged, durable design
  • Field-proven in thousands of applications worldwide
  • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight

SR5 Alternator

  • Superior motor starting capability minimizes need for oversizing alternator
  • Designed to match performance and output characteristics of Cat diesel engines
  • Robust Class H insulation

EMCP 4 Control Panel

  • User-friendly interface and navigation
  • Scalable system to meet a wide range of installation requirement
  • Expansion modules and site-specific programming for specific customer requirements

Cooling System

        
  • Designed to operate in standard ambient temperatures up to 50ยฐC (122ยฐF)
  •     
  • Contact your Cat Dealer for specific ambient and altitude capabilities

Standard Equipment

Air Inlet System
  • Air cleaner
  • Single element canister type with service indicator
Control Panel
  • Environmental sealed front face
  • Warning/shutdown with common LED indication of shutdowns for:
  • Overspeed
  • RPM
  • Generator phase sequence
Exhaust
  • Exhaust flange outlet
Fuel
  • Primary fuel filter with integral water separator
Generator
  • IP23 Protection
  • Matched to the performance and output characteristics of Cat engines
Power Termination
  • Busbar
Starting/Charging
  • Heavy duty starting system
  • Charging alternator
Cooling System
  • Caterpillar extended life coolant
  • Radiator fan and fan drive
  • Fan and belt guards
  • JWAC
  • Coolant drain line with valve
Cooling
  • Package mounted radiator
Exhaust System
  • Dry exhaust manifold
  • Flanged faced outlet(s)
Fuel System
  • Secondary fuel filters
  • Fuel priming pump
  • Fuel cooler; not included with packages without radiator
  • Flexible fuel lines - shipped loose
Generators and Attachments
  • Internal excitation (IE)
  • 6 Lead
  • Busbar connections, top center mounted, top cable entry
  • IEC standard hole pattern
  • Random wound
Governing System
  • ADEM III
Literature
  • Parts book
Lube System
  • Lubricating oil
  • Oil filter, filler and dipstick
  • Fumes disposal
  • Oil drain lines and valve
  • Gear type lube oil pump
Mounting System
  • Rubber anti-vibration mounts - shipped loose
  • Rails - Engine/generator/radiator mounting
Starting / Charging System
  • Battery and battery rack w/cables
  • 24 Volt electric starting motor
  • Battery disconnect switch
General
  • Right hand servicing
  • Paint - Caterpillar yellow with high gloss black rails & radiator
  • Flywheel and flywheel housing-SAE No. 00
  • SAE standard rotation

Optional Equipment

Air Inlet System

  • Air inlet protection
  • Heavy duty air cleaners
  • Remote air inlet adapters
  • Dual element air cleaners

Circuit breakers

  • Cable entry options
  • Control packaging for enclosures
  • Optional busbar power connections
  • EMAX breakers
  • Load take off; IEC standard hole

Power Termination

  • Circuit breakers, IEC compliant

Control Panels

  • External box clips
  • Local and remote monitoring
  • Busbar connections
  • Governors
  • Generator temperature monitoring

Cooling System

  • Optional Serpentine radiators
  • Water level switch gauges
  • Heat exchangers
  • Radiator duct flanges

European Certifications

  • EU Declaration of Conformity

Exhaust System

  • Mufflers
  • Through wall installation kit
  • Flexible fittings
  • Muffler mounting kits

Fuel System

  • Fuel coolers
  • Primary fuel filter

Generators and attachments

  • 3 Phase, Random wound, Internal excitation (IE)
  • Internal excitation (IE)
  • Random wound
  • Pitch: 0.6667
  • Optional generators

Instrumentation

  • Thermocouples
  • Pyrometers and thermocouples

Lube System

  • Manual prelube sump pumps
  • Oil level regulator
  • Electric prelube pumps

Mounting System

  • Spring type vibration isolators
  • IBC vibration isolators

Protection System

  • Explosion relief valves

Special Tests / Reports

  • PGS Test report @ 0.8 power factor
  • CSA test and certification
  • Neutral ground certificate
  • PGS Test report @ 1.0 power factor
  • IBC seismic Certification

Starting / Charging System

  • Jacket water heaters
  • ETHER starting aids
  • Dual 24 volt electric starting motors
  • 24 Volt battery set - Dry
  • Charging alternators - 50 Amp

General

  • Engine barring group