• Banner
Diesel Generator Sets

Caterpillar and your local Cat® Dealer are ready for all your power generation demands. From diesel and gas generator sets to uninterruptible power supplies, automatic transfer switches and electrical switchgear, our experienced worldwide dealer network can deliver the power systems and support you need.

3516B Generator Set

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

  • Specification Summary

  • Minimum Rating 1750 kVA
  • Maximum Rating 2500 kVA
  • Voltage 220 to 13800
  • Frequency 50 Hz
  • Specification Sheet

    Download

Product Details

Generator Set Specifications

Minimum Rating 1750 kVA
Maximum Rating 2500 kVA
Voltage 220 to 13800
Frequency 50 Hz
Speed 1500 rpm

Generator Set Configurations

Emissions/Fuel Strategy Low Fuel Consumption, Low Emissions

Engine Specifications

Engine Model 3516B TA, V-16, 4-Stroke Water-Cooled Diesel
Displacement - HD 78.08 l
Displacement - Std 69 l
Fuel System Electronic unit injection
Aspiration TA
Governor Type Adem™3
Compression Ratio 14.0:1 Std 15.5:1 HD
Bore 170 mm
Stroke - HD 215 mm
Stroke - Standard 190 mm

Generator Set Dimensions

Length - Maximum 5928 mm
Width - Maximum 2286 mm
Height - Maximum 2367 mm
  • Air Inlet
    •  Air Cleaner
  • Cooling
    •  Package mounted radiator
  • Exhaust
    •  Exhaust flange outlet
  • Exhaust flange outlet
    • Fuel
      •  Primary fuel filter with integral water separator
      •  Secondary fuel filter
      •  Fuel priming pump
    • Generator
      •  Matched to the performance and output characteristics of Cat engines
      •  IP23 Protection
    • Power Termination
      •  Bus Bar
    • Bus Bar
      • Control Panel
        •  EMCP 4 Genset Controller
      • General
        •  Paint - Caterpillar Yellow except rails and radiators gloss black
      • Paint - Caterpillar Yellow except rails and radiators gloss black
        • Exhaust
          •  Exhaust mufflers <!--(except Tier 4)-->
        • Generator
          •  Anti-condensation heater
          •  Internal excitation (IE)
          •  Permanent magnet excitation (PMG)
          •  Oversize and premium generators
        • Power Termination
          •  Circuit breakers, UL listed
          •  Circuit breakers, IEC compliant
        • Control Panels
          •  EMCP 4.2
          •  EMCP 4.3
          •  EMCP 4.4
          •  Generator temperature monitoring & protection
          •  Load share module
          •  Digital I/O module
          •  Remote monitoring software
        • EMCP 4.2
          • EMCP 4.3
            • EMCP 4.4
              • Generator temperature monitoring & protection
                • Load share module
                  • Digital I/O module
                    • Remote monitoring software
                      • Mounting
                        •  Rubber anti-vibration mounts
                        •  Spring-type vibration isolator
                        •  IBC isolators
                      • Rubber anti-vibration mounts
                        • Spring-type vibration isolator
                          • IBC isolators
                            • Starting/Charging
                              •  Battery chargers
                              •  Oversize batteries
                              •  Jacket water heater
                              •  Heavy-duty starting system
                              •  Charging alternator
                              •  Air starting motor with control and silencer
                            • Battery chargers
                              • Oversize batteries
                                • Jacket water heater
                                  • Heavy-duty starting system
                                    • Charging alternator
                                      • Air starting motor with control and silencer
                                        • General
                                          •  The following options are based on regional and product configuration:
                                          •  Seismic Certification per applicable building codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007
                                          •  UL 2200 package
                                          •  EU Certificate of Conformance (CE)
                                          •  CSA Certification
                                          •  EEC Declaration of Conformity
                                          •  Enclosures: sound attenuated, weather protective
                                          •  Automatic transfer switches (ATS)
                                          •  Integral & sub-base fuel tanks
                                          •  Integral & sub-base UL listed dual wall fuel tanks

                                        9 Similar Products Available in Used

                                        View

                                        Signup to Al-Bahar Monthly newsletter and stay connected!

                                        We respect your privacy and will never share or sell your information.