ATS MX Contactor

Caterpillar and your local Cat® Dealer are ready for all your power generation demands. From diesel and gas generator sets to uninterruptible power supplies, automatic transfer switches and electrical switchgear, our experienced worldwide dealer network can deliver the power systems and support you need.

CTS Series Automatic Transfer Switch


The Cat® CTS Series Automatic Transfer Switch(ATS)is configurable for applications requiring the dependability and ease of operation found in a full featured power contactor type transfer switch.

The CTS Series is equipped with the MX250 controller that is designed for the most demanding transfer or bypass switch applications.

  • Specification Summary

  • Rating Range 40 to 4000A
  • Transfer Type Open transition
  • Switch Type Contactor Based
  • Control Power 40 to 4000 amperes, 2, 3 or 4 Poles
  • Specification Sheet

    Download

Product Details

Technical Summary

Rating Range 40 to 4000A
Transfer Type Open transition
Switch Type Contactor Based

Electrical Ratings

Control Power 40 to 4000 amperes, 2, 3 or 4 Poles
Enclosure Capability NEMA 1, 3R, 4, 4X and 12
System Voltage Application Available to 600 VAC, 50 or 60 Hz
Applicable Testing UL 1008 listed at 480 VAC <br>CSA C22.2 No. 178 certified at 600 VAC <br> IEC 947-6-1 listed through 480 VAC
  • The Cat CTS Series of Automatic Transfer Switches
    •  The Cat CTS Series power contactor type transfer switch makes use of a fully programmable / configurable microprocessor-based controller to allow the utmost in application flexibility. Further, the CTS Series is offered in a wide array of configurations en
  • The Cat CTS Series power contactor type transfer switch makes use of a fully programmable / configurable microprocessor-based controller to allow the utmost in application flexibility. Further, the CTS Series is offered in a wide array of configurations en
    • 40-4000 Amps:
      •  CTS Automatic Transfer Switches
      •  CTSD Delayed Transition Transfer Switches
      •  CTSM Manual Transfer Switches
    • CTS Automatic Transfer Switches
      • CTSD Delayed Transition Transfer Switches
        • CTSM Manual Transfer Switches
          • 100-4000 Amps:
            •  CTSCT Closed Transition Transfer Switches
            •  CBTS Automatic Transfer/Bypass Switches
            •  CBTSD Delayed Transition Bypass Switches
            •  CBTSCT Closed Transition Bypass Switches
          • All CTS products meet or exceed industry requirements to allow specification and installation with confidence.
            •  UL 1008 listed through 480 VAC
            •  CSA C22.2 No. 178 listed through 600 VAC
            •  IEC 947-6-1 listed through 480 VAC
            •  Codes and Standards: NFPA 0,99, 101,110,NEC 517,700,701,702,IEEE 446, 241,NEMA ICS2-447
            •  Controls tested in accordance with:
            •  Equipment (Controls and Power Section)Seismic Test Qualified to:<br>IBC-2003 <br>IEEE-693-2005
            •  Enclosures meet the requirements of:<br>UL 508, UL 50, ICS 6, ANSI C33.76 and NEMA 250
            •  Quality System:<br>ISO 9001 Registered
            •  This ruggedly built family of power contactor switches has been specifically designed for transfer switch duty with dependability, versatility and user friendliness of prime concern.<br>The CTS power panel components, consisting of power switching co
          • CTS Series Method of Operation
            •  When the normal source fails or the voltage drops to a predetermined point (usually 80% of nominal), if required, a circuit is closed to start the engine generator set. When the emergency source reaches 90% of rated voltage and 95% of rated frequency, the
          • When the normal source fails or the voltage drops to a predetermined point (usually 80% of nominal), if required, a circuit is closed to start the engine generator set. When the emergency source reaches 90% of rated voltage and 95% of rated frequency, the
            • Drive Mechanism
              •  All CTS switches employ the simple “over-center” principle to achieve a mechanically locked position in either normal or emergency and a high speed drive assures contact transfer in 100 ms or less. High contact pressure and positive mechanical